©Copyright Shenzhen Hehejin Industrial Co., LTD. All rights reserved. Site Map
This is a multifunctional off grid solar inverter, integrated with a MPPT solar charge controller, a high frequency pure sine wave inverter and a UPS function module in one machine, which is perfect for off grid backup power and self-consumption applications. This inverter can work with or without batteries. The whole system also need other devices to achieve complete running such as PV modules, generator, or utility grid.
Current:
|
|
Model:
|
|
PowMr 6KW 12KW 48V SPF Series Solar System Off Grid Tie Inverter
Features
Brand:PowMr
Product Model: SPF 6000T DVM
Rated power 3.5KW to 5KW, power factor 1
MPPT ranges 120V~430V, 450Voc
High frequency inverter with small size and light weight
Pure sine wave AC output
Solar and utility grid can power loads at the same time
With CAN/RS485 for BMS communication
With the ability to work without battery
Parallel operation up to 6 unit (only with battery connected)
WIFI/ GPRS remote monitoring (optional)
Overview
This is a multifunctional off grid solar inverter, integrated with a MPPT solar charge controller, a high frequency pure sine wave inverter and a UPS function module in one machine, which is perfect for off grid backup power and self-consumption applications.
1.Brand: PowMr
2. Product Model: SPF 6KT HVM
3.The WiFi / GPRS module is a plug-and-play monitoring device to be installed on the inverter. With this device, users can monitor the status of the PV system from the mobile phone or from the website anytime anywhere.
Model | SPF 6KT HVM | SPF 12KT HVM | |
Battery Voltage | 48VDC | 48VDC | |
Rated Power | 6KW | 12KW | |
Surge Rating(20ms) | 18KW | 36KW | |
Waveform | Pure sine wave/ same as input(bypass mode) | ||
Nominal Output Voltage | 208V-220V-230V-240Vac(+/-10% RMS) | ||
Output Frequency | 50Hz/60Hz(+/-0.3Hz) | ||
Inverter Efficiency(Peak) | >85% | ||
Line Mode Efficiency | >95% | ||
Power Factor | 1.0 | ||
Maximum PV Charge Current | 80A | 120A | |
DC Voltage | 48V | ||
Maximum PV Array Power | 5000W | 7000W | |
MPPY Operating Voltage(VDC) | 60-145V | ||
Max. PV Array Open Circuit Voltage | 150VDC | ||
Maximum Efficiency | >98% | ||
Low DC Cut-Off Voltage(Only Lead Acid) | Default @load<20%: 42.0V; @20%≤load<50%: 40.8V; @load≥50%: 38.4V (Based on Program 21, default 42.0V ,40Vdc~48Vdc settable) | ||
Low DC Warning Voltage(Only Lead Acid) | Low DC Cut-Off Voltage +2Vdc | ||
Low DC Warning Return Voltage (Only Lead Acid) | >48 | ||
Low DC Warning SOC(Only Li) | <Low DC Cut-off SOC +5% | ||
Low DC Warning Return SOC (Only Li) | >Low DC Cut-off SOC +15% | ||
Low DC Cut-off SOC(Only Li) | Default 20%,5%~50% Settable | ||
Cold Start SOC(Only Li) | >Low DC Cut-off SOC +10% | ||
High DC Recovery Voltage | 50VDC | ||
High DC Cut-off Voltage | AGM:0V, FLD:62V, USE or Li Mode: C.V. Voltage+4V | ||
Voltage | 230VAC | ||
Selectable Voltage Range | 154~272VAC(for appliances),184~272VAC(for UPS) | ||
Frequency Range | 50Hz/60Hz(Auto sensing) | ||
Maximum Charge Current | 60A | 100A | |
Typical Transfer Time | 10ms | ||
Overload Protection(SMPS Load) | Circuit breaker | ||
Output Short Circuit Protection | Circuit breaker | ||
Dimensions(W*H*D) | 540*360*218mm | 650*380*225mm | |
Net Weight(kg) | 45 | 75 | |
Gross Weight(kg) | 50 | 94 | |
Operation Temperature Range | 0℃ to 50℃ | ||
Storage Temperature | -20℃ to 60℃ |