Shenzhen Hehejin Industrial Co., LTD.

PowMr 12V 24V 20A/30A/40A MPPT Solar Charge Controller Lead-acid Battery PowMr 12V 24V 20A/30A/40A MPPT Solar Charge Controller Lead-acid Battery

MSC-N series is a new generation of the solar controller with a two-way load output. The two-way load output voltage can be switched to 12V or 24V DC freely by an enable switch. According to the battery voltage, the two-way load output voltage can be turned off in stages to ensure the load1 output. The two-way load output adopts a high-efficiency buck-boost conversion circuit, which greatly reduces the invalid loss of the battery and improves the service time of the battery.

  • Brand : PowMr
  • Product Name : MSC3210N
Current:
  • 20A
  • 30A
  • 40A
Model:
  • MSC2210N
  • MSC3210N
  • MSC4210N
  • MSC4215N
WHS Location:
Share this:

Description

PowMr 12V 24V 20A/30A/40A MPPT Solar Charge Controller Lead-acid Battery 


Features

  • Brand:PowMr

  • Product Model: MSC3210N

  • High quality and low failure rate components of ST or IR to ensure the service life;

  • Advanced MPPT technology & ultra-fast tracking speed guarantee tracking efficiency up to 99.5%;

  • Maximum DC/DC transfer efficiency up to 98.6%, full load efficiency up to 96.6 %;

  • Accurate recognizing and tracking technology of multi-peaks maximum power point;

  • Wider MPP running voltage to increase the utilization ratio of PV modules;

  • Support the lead-acid and lithium batteries, programmable temperature compensation;

  • High temperature charging automatic power reduction function;

  • The freely set voltage level of the two-way load output, especially suitable for voltage-sensitive loads;

  • Configurable cut-off voltage value for the two-way load output;

  • Support no-battery mode, PV array powers the load directly ①;

  • High-efficiency buck-boost  control chip and power device,  conversion efficiency up to 98.9%;

  • Optional charging prior mode and load prior mode;

  • Effectively prolong the running time of load one by the discontinuous power supply in load prior mode;

  • Customized the load two output according to the actual requirement;

  • Common negative design, used in a negative grounded system;

  • Real-time monitor controller by an external remote meter, BT module, Wifi module or PC software;

  • Comprehensive electronic protections.

Overview

Appreciate you for choosing MPPT solar charge controller. MSC-N series is a new generation of the solar controller with a two-way load output. The two-way load output voltage can be switched to 12V or 24V DC freely by an enable switch. Also optimized the following points:

1.Brand: PowMr

2. Product Model: MSC3210N

3.Increase all kinds of protection function to be used more reassuring.

4.High temperature charging automatic power reduction function.

5.Optional charging prior mode and load prior mode.

Others

1.1 Protection

Protection

Instruction

PV limit Current/limit   power protection

When the charging current/power   of the PV array exceeds the rated charging current/power, the PV array will   charge the battery as per the rated charging current/power.

PV short circuit protection

When not in the PV charging state, the   controller will not be damaged in the case of a short-circuiting in the PV   array.

PV reverse polarity   protection

When the polarity of the PV   array is reversed, the controller may not be damaged and resume normal   operation after the mis-wiring is corrected.

NOTE: If the PV array is reversed and the   actual power of the PV array is 1.5 times the rated power of the controller,   the controller will be damaged.

Night reverse charging   protection

Prevent the battery from   discharging to the PV module at night.

Battery reverse protection

When the polarity of the battery is reversed,   the controller may not be damaged and resume normal operation after the   mis-wiring is corrected.

NOTE: Limited to   the characteristic of lithium battery, when the PV array connection right and   battery connection reversed, the controller will be damaged.

Battery over voltage   protection

When the battery voltage reaches the   over voltage disconnect voltage, the PV array will automatically stop   charging the battery to prevent battery damage due to over charging.

Battery over discharging   protection

When the battery voltage reaches the   low voltage disconnect voltage, battery discharging will be automatically   stopped to prevent battery damage due to over discharging.

Battery over heating   protection

The controller detects the battery   temperature through an external temperature sensor. The battery will stop   working when its temperature exceeds 65 °C and will resume when its   temperature is below 55 °C.

Lithium battery low   temperature protection

When the temperature detected by the   temperature sensor is lower than the Low Temperature Protection Threshold (LTPT),   the controller will stop charging and discharging automatically. When the   detected temperature is higher than the LTPT, the controller will be working   automatically (The LTPT is 0 °C by default and can be set within the range of   10 ~ -40 °C).

Load short circuit   protection

When the load is short-circuited,   the controller will cut off the output and automatically resume the output   when the short circuit is released.

Overload protection

If the load current exceeds   1.05 times the controller's rating current, the controller will cut off the   output after 30 seconds delay. In case of overload, the controller is   restarted at intervals of 5 seconds, 10 seconds, 15 seconds, 20 seconds, 25   seconds, 30 seconds and 1 hour until the power of all the loads is reduced to   the rated power.

Device over heating   protection

An internal temperature sensor can   detect the internal temperature of the controller. The controller stops   working when the internal temperature exceeds 85 °C and resume work when the   internal temperature is below 75 °C.

TVS   high voltage transients protection

The internal circuitry of the   controller is designed with Transient Voltage Suppressors (TVS), which can   only protect against high-voltage surge pulses with less energy. If the   controller is to be used in an area with frequent lightning strikes, it is   recommended to install an external surge arrester.

When the internal temperature of the controller reaches 81, the charging power automatic reduction function will be enabled. Every increase of one , the charging power will be reduced by 5%, 10%, 20%, and 40%. If the internal temperature is higher than 85, the controller will stop charging the battery. When the internal temperature of the controller declines to 75 ºC or lower, the controller will resume.

For example MSC4215N 24V system:

clip_image002.gif

 

 

1.2 Troubleshooting

Faults

Possible reasons

Solutions

Charging   LED is OFF during daytime when sunshine falls on PV array properly

PV   array open circuit

Confirm whether the connection of PV   array is correct and tight

Wire   connection is correct; the controller is not working.

Battery   voltage is lower than 8V

Please check the voltage of the battery(at   least 8V voltage to activate the controller).

Charging   indicator Green fast flashing

Battery   over voltage

Check whether the battery voltage is   higher than OVD (over voltage disconnect voltage), and disconnect the PV   array connection.

The battery   indicator is in red on solid

Battery   over discharged

① Automatically restore load output   after the battery is fully charged.

Other ways recharge the battery.

Battery   indicator flashes red slowly

Battery   over heating

While the temperature decline to be   below 55 ºC, the controller will resume.

Fault   indicator on solid, PV and battery Indicators flash orange fast

Controller   over heating

When the heat sink of the controller   exceeds 85, the controller will automatically cut off the   input and output circuit. When the temperature below 75, the controller will resume work.

System   voltage error

① Check whether the current battery   voltage matches the system voltage set by the controller.

② Please change a suitable battery or   reset the system voltage.

Fault indicator   on solid, load off.

Over   load

Please   reduce the number of electric equipment.

② Restart the controller or press the   button to clear faults.

Fault   indicator on solid, load off.

Load   short circuit

Check carefully loads connection, clear the   fault, Restart the controller, or press the button to   clear faults.

① If the load current exceeds 1.05 times the controller's rating current, the controller will cut off the output after 30 seconds delay. In case of overload, the controller is restarted at intervals of 5 seconds, 10 seconds, 15 seconds, 20 seconds, 25 seconds, 30 seconds and 1 hour until the power of all the loads is reduced to the rated power.

1.3 Maintenance

The following inspections and maintenance tasks are recommended at least two times per year for the best performance.

  • Make sure no block on airflow around the controller. Clear up any dirt and fragments on the radiator.

  • Check all the naked wires to make sure insulation is not damaged for sun exposure, frictional wear, dryness, insects or rats, etc. Repair or replace some wires if necessary.

  • Verify the indicator display is consistent with the actual operation. Pay attention to any troubleshooting or error indication. Take corrective action if necessary.

  • Confirm that all terminals have no corrosion, insulation damaged, high temperature or burnt/discolored sign, tighten terminal screws to the suggested torque.

  • Clear up dirt, nesting insects, and corrosion in time.

  • Replace a new surge arrester in time to avoid damaging the controller and even other equipment.

    clip_image003.pngWARNINGRisk of electric shock! Make sure that all the power is turned off before the above operations, and then follow the corresponding inspections and operations.




Technology Parameter

Model

MSC2210N

MSC3210N

MSC4210N

MSC4215N

Battery   rated voltage

12/24DC   Auto-recognition

24VDC

Rated   charging current

20A

30A

40A

Controller   working voltage range

8~32V

16~32V

Max.   PV open circuit voltage

100V(lowest   temperature)

92V(At   25 operating environment temperature)

150V(lowest   temperature)

138V(aT   25 operating environment temperature)

MPPT   voltage range

(Battery   voltage +2V)~72V

(Battery   voltage +2V)~108V

Rated   charging power

260W/12V   520W/24V

390W/12V   780W/24V

1040W/24V

Max.   Conversion efficiency

98.30%

98.60%

98.60%

Full   load effciency

96.40%

96.60%

96.50%

Self-consumption

35mA(12V) 22mA(24V)

Load   1/2 constant-voltage output voltage

DC   12V/24V(configurable)

Load   rated power

Load   1:100w

Load   2: 36W

Load   output protection voltage

Load   1 98.9%; Load 2 97.1%

Load   1 97.4%; Load 2 96.0%

Temperature   compensate coeffiency

-3mV//2V(Default)

Grounding   Type

Common   negative

Communication   port

RS485

Working   temperature

-30~+65(when the working temperature   reaches 50, the charging power and load power will be reduced appropriately,   working of full load is not supported.)

Storage   temperature

-20~ +70

Dimension

173×158×77.1mm

178×162×80.1mm

213.2×192×96.6mm

Net   Weight

1.3kg

1.5kg

2.0kg

2.0kg


×

Contact Us

captcha