This is a multi-function inverter/charger, 5500W Solar Hybrid Inverter Pure Sine Wave 48V 220VAC with Build In 100A MPPT Solar Charger, combining functions of inverter, solar charger and battery charger to offer uninterruptible power support with portable size.
Powmr 5500W 48V Solar Inverter With 100A MPPT Solar Charger
Pure sine wave inverter
Configurable input voltage range for home appliances and personal
computers via LCD setting
Configurable battery charging current based on applications via LCD setting
Configurable AC/Solar Charger priority via LCD setting
Compatible to mains voltage or generator power
Auto restart while AC is recovering
Overload/ Over temperature/ short circuit protection
Smart battery charger design for optimized battery performance
Cold start function
Removable LCD control module
Communicate with RS-232(WIFI/GPRS Optional)
Configurable AC/PV Output usage timer and prioritization
Anti-dust kit(Optional)
The following illustration shows basic application for this inverter/charger. It also includes following devices to have a complete running system:
Generator or Utility.
PV modules
Consult with your system integrator for other possible system architectures depending on your requirements.
This inverter can power all kinds of appliances in home or office environment, including motor-type appliances
such as tube light fan, refriaerator and air conditioner.
1. LCD display
2. Status indicator
3. Charging indicator
4. Fault indicator
5. Function buttons
6. Power on/off switch
7. AC input
8. AC output
9. PV input
10. Battery input
11. Circuit breaker
12. RS-232 communication port (WIFI /GPRS/ Removable box)
13. Removable box
INSTALLATION
1.1 Unpacking and Inspection
Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You should have received the following items inside of package:
The unit x 1 User manual x 1 DC Fuse x 1 Ring terminal x 1 Strain relief plate x 1 PV wire cover x 1 Screws x 4 Dust cover x 1
1.2 Preparation
Before connecting all wirings, please take off bottom cover by removing four screws as shown below. A Notice:Slowly remove wire cover.There is a communication cable connect to the main board
1.1 Mounting the Unit
Consider the following points before selecting where to install: Do not mount the inverter on flammable construction materials.Mount on a solid surface Install this inverter at eye level in order to allow the LCD display to be read at all times.3S For proper air circulation to dissipate heat, allow a clearance of approx. 20 cm to the side and approx. 50 cm above and below the unit.The ambient temperature should be between 0°C and 55°C to ensure optimal operation.The recommended installation position is to be adhered to the wall vertically.Be sure to keep other objects and surfaces as shown in the diagram to guarantee sufficient heat dissipation and to have enough space for removing wires.
INVERTER MODEL | 3.5KW 5.5KW | ||
Input Voltage Waveform | Sinusoidal (utility or generator) | ||
Nominal Input Voltage | 230Vac | ||
Low Loss Voltage | 170Vac±7V (UPS); 90Vac±7V (Appliances) | ||
Low Loss Return Voltage | 180Vac±7V (UPS); 100Vac±7V (Appliances) | ||
High Loss Voltage | 280Vac±7V | ||
High Loss Return Voltage | 270Vac±7V | ||
Max AC Input Voltage | 300Vac | ||
Nominal Input Frequency | 50Hz/ 60Hz (Auto detection) | ||
Low Loss Frequency | 40±lHz | ||
Low Loss Return Frequency | 42±lHz | ||
High Loss Frequency | 65±lHz | ||
High Loss Return Frequency | 63±lHz | ||
Output Short Circuit Protection | Circuit Breaker | ||
Efficiency (Line Mode) | >95% ( Rated R load, battery full charged ) | ||
Transfer Time | 10ms typical (UPS); 20ms typical (Appliances) |
INVERTER MODEL
INVERTER MODEL | 3.5KW | 5.5KW |
Rated Output Power | 3.5KW | 5.5KW |
Output Voltage Waveform | Pure Sine Wave | |
Output Voltage Regulation | 230Vac±5% | |
Output Frequency | 50Hz | |
Peak Efficiency | 93% | |
Overload Protection | 5s@>150% load; 10s@110%-150% load | |
Surge Capacity | 2* rated power for 5 seconds | |
Nominal DC Input Voltage | 24Vdc | 48Vdc |
Cold Start Voltage | 23.0Vdc | 46.0Vdc |
Low DC Warning Voltage @ load < 50% | 22.0Vdc | 44.0Vdc |
@ load > 50% | 21.0Vdc | 42.0Vdc |
Low DC Warning Return Voltage @ load < 50% | 22.5Vdc | 45.0Vdc |
@ load > 50% | 22.0Vdc | 44.0Vdc |
Low DC Cut-off Voltage @ load < 50% | 20.5Vdc | 41.0Vdc |
@ load > 50% | 20.0Vdc | 40.0Vdc |
High DC Recovery Voltage | 32Vdc | 62Vdc |
High DC Cut-off Voltage | 33Vdc | 63Vdc |
No Load Power Consumption | <35W |
Utility Charging Mode
Utility Charging Mode | |||
INVERTER MODEL | 3.5KW | 5.5KW | |
Charging Algorithm | 3-Step | ||
AC Charging Current (Max) | 80Amp (@Vi/P=230Vac) | 80 Amp (@Vi/p=230Vac) | |
Bulk Charging Voltage | Flooded Battery | 29.2 | 58.4 |
AGM / Gel Battery | 28.2 | 56.4 | |
Floating Charging Voltage | 27Vdc | 54Vdc | |
MPPT Solar Charging Mode | |||
INVERTER MODEL | 3.5KW | 5.5KW | |
Max. PV Array Power | 5000W | 6000W | |
Nominal PV Voltage | 240Vdc | ||
PV Array MPPT Voltage Range | 120-450Vdc | ||
Max. PV Array Open Circuit Voltage | 500Vdc | ||
Max Charging Current (AC charger plus solar charger) | lOOAmp 100 Amp |
General Specifications
INVERTER MODEL | 3.5KW | 5.5KW |
Safety Certification | CE | |
Operating Temperature Range | -10°C to 50°C | |
Storage temperature | -15°C- 60°C | |
Humidity | 5% to 95% Relative Humidity (Non-condensing) | |
Dimension (D*W*H), mm | 440X302X138 | |