©Copyright Shenzhen Hehejin Industrial Co., LTD. All rights reserved. Site Map
PowMr 3000W Hybrid Inverter,Pure Sine Wave Inverter DC to 220-230VAC with 80A MPPT Charge Controller,Support Utility/Generator/Solar Charge and Bluetooth LCD USB Control, for 24v Lead-Acid and Lithium
Power Options:
|
|
Features
1.Pure sine wave inverter
2.Configurable input voltage ranges for home appliances and personal computers via LCD control panel
3.Configurable battery charging current based on applications via LCD control panel
4.Configurable AC/Solar Charger priority via LCD control panel
5.Compatible to utility mains or generator power
6.Auto restart while AC is recovering
7.Overload / Over temperature / short circuit protection
8.Smart battery charger design for optimized battery performance
9.Cold start function
10.Removable LCD control module
11.Multiple communication ports for BMS (RS485, CAN-BUS, RS232)
12.Built-in Bluetooth for Android mobile monitoring (Requires App Watch Power), OTG USB function, dusk filters
13.Configurable AC/PV Output usage timer and prioritization
Utility first:
Utility will provide power to the loads as first priority.Solar and battery energy will provide power to the loads only when utility power is not available.
Solar first
Solar energy provides power to the loads as first priority.If solar energy is not sufficient to power all connected loads,Utility energy will supply power to the loads at the same time.
SBU priority
Solar energy provides power to the loads as first priority.If solar energy is not sufficient to power all connected loads, battery energy will supply power to the loads at the same time. Utility provides power to the loads only when battery voltage drops to either low-level warning voltage or the setting point in program 12.
Solar first
Solar energy will charge battery as first priority.
Utility will charge battery only when solar energy is not available.
Solar and Utility (default)
Solar energy and utility will charge battery at the same time.
Only Solar
Solar energy will be the only charger source no matter utility is available or not.
Inverter Model | 3KW | 5KW | |
Input voltage Waveform | Sinusoidal(Utility or generator) | ||
Nominal Input Voltage | 230Vac | ||
Low Loss Voltage | 170Vac±7V(UPS) 90Vac±7V(Appliances) | ||
Low Loss Return Voltage | 180Vac±7V(UPS) 100Vac±7V(Appliances) | ||
High Loss Voltage | 280Vac±7V | ||
High Loss Return Voltage | 270Vac±7V | ||
Max AC Input Voltage | 300Vac | ||
Nominal Input Frequency | 50Hz/60Hz(Auto detection) | ||
Low Loss Frequency | 40±1Hz | ||
Low Loss Return Frequency | 42±1Hz | ||
High Loss Frequency | 65±1Hz | ||
High Loss Return Frequency | 63±1Hz | ||
Output Short Circuit Protection | Circuit Breaker | ||
Efficiency(Line Mode) | ﹥95%(Rated R load,battery full charged) | ||
Transfer Time | 10ms typical (UPS);20ms typical(Appliances) | ||
Output Power derating: | When AC input voltage drops to 170V,the output power will be derated; When AC input voltage to 90V, the output power will be 50% | ||
Rated Output Power | 3KVA/3KW | 5KVA/5KW | |
Output Voltage Waveform | Pure Sine Wave | ||
Output Voltage Regulation | 230Vac±5V | ||
Peak Efficiency | 93% | ||
Overload Protection | 5s@≧130%load;10s@105~130%load | ||
Surge Capacity | 2*rated power for 5 seconds | ||
Nominal DC Input Voltage | 24Vdc | 48Vdc | |
Cold Start Voltage | 23.0Vdc | 46.0Vdc | |
Low DC Warning Voltage @load﹤50% @load≧50% |
23.0Vdc 22.0Vdc |
46.0Vdc 44.0Vdc | |
Low DC Warning Return Voltage @load﹤50% @load≧50% |
23.5Vdc 23.0Vdc |
47.0Vdc 46.0Vdc | |
Low DC Cut-off Voltage @oad﹤50% @oad≧50% |
21.5Vdc 21.0Vdc |
43.0Vdc 42.0Vdc | |
High DC Recovery Voltage | 32 Vdc | 62 Vdc | |
High DC Cut-off Voltage | 33Vdc | 63Vdc | |
No Load Power Consumption | ﹤35W | ﹤50W | |
Utility Charging Mode | |||
Charge Algorithm | 3-Step | ||
AC Charge Current(Max) | 40Amp(@V i/p=230Vac) | 60Amp(@V i/p=230Vac) | |
Bulk Charging Voltage | Flooded Battery | 29.2 | 58.4 |
AGM/GEL Battery | 28.2 | 56.4 | |
Floating Charging Voltage | 27Vdc | 54Vdc | |
MPPT Solar Charging Mode | |||
Max PV Array Power | 4000W | 5000W | |
Nominal PV Voltage | 240Vdc | 320Vdc | |
Start-up Voltage | 150Vdc±10Vdc | ||
PV Array MPPT Voltage Range | 120~450Vdc | ||
Max PV Array Open Circuit Voltage | 500Vdc | ||
Max Charge Current (AC Charger plus solar charger) | 80Amp | ||
Operating Temperature Range | -10℃ to 50℃ | ||
Storage temperature | -10℃ to 60℃ | ||
Humidity | 5% to 95% Relative Humidity(Non-condensing) | ||
Dimension(D*W*H),mm | 115*300*400 | ||
Net Weight,kg | 10.5 | 11.7 |